Technical Data
Cable family code |
IFAF
|
Cable type |
FiTH Cable
|
Cable version |
Gel-free installation cable
|
Cable application |
indoor use
|
CPR classification |
Dca-s1a,d0,a1
|
DoP number |
D9087
|
Fiber type |
G.657.A2
|
Fiber count |
2
|
Fiber color coding |
1.–4.: red, green, blue, yellow
|
Loose tube count |
1
|
Loose tube diameter |
1,15 mm
|
Outer sheath material |
FRLSZH
|
Outer sheath color |
yellow
|
Cable outer diameter |
2,3 mm
|
Cable weight |
5.5 kg/km / 4 lbs/1000ft
|
DIN / VDE 0888 code |
J-B(ZN)H
|
Warranty |
R&Mfreenet
|
Expected lifetime |
min. 30 years
|
CPR test method |
EN 50575, EN 13501-6
|
Standard put-up length on drum |
2’100 m ± 5%
|
CPR classification |
Dca
|
Mechanical Data
Installation tensile strength |
200 N (5 min)
|
Installation tensile strength acceptance criteria |
Δα ≤ 0,05 dB
|
Installation tensile strength test method |
IEC 60794-1-21:E1
|
Crush resistance long term |
400 N/100mm (15 min)
|
Long-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB prior release, no damage
|
Long-term crush resistance test method |
IEC 60794-1-21:E3A
|
Short-term crush resistance |
1000 N/100mm
|
Short-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB after release, no damage
|
Short-term crush resistance test method |
IEC 60794-1-21:E3A
|
Impact resistance |
3 Nm, 3 impacts, d=20 mm, R=12.5 mm
|
Impact resistance acceptance criteria |
Δα ≤ 0,05 dB after test, no damage
|
Impact resistance test method |
IEC 60794-1-21:E4
|
Kink |
d=4 x cable diameter
|
Kink acceptance criteria |
no kink
|
Kink test method |
IEC 60794-1-21:E10
|
Repeated bending |
R=20 x cable diameter, 25 cycles
|
Repeated bending acceptance criteria |
no damage
|
Repeated bending test method |
IEC 60794-1-21:E6
|
Cable bend |
d=20 x cable diameter, 4 turns, 3 cycles
|
Cable bend acceptance criteria |
Δα ≤ 0,05 dB after test, no damage
|
Cable bend test method |
IEC 60794-1-21:E11A
|
Minimum bend radius in service |
35 mm
|
Minimum bend radius during installation |
45 mm
|
Environmental Characteristics
Temperature cycling |
-10 °C +60 °C / +14 °F +140 °F
|
Temperature cycling acceptance criteria |
Δα ≤ 0,05 dB
|
Temperature cycling test method |
IEC 60794-1-22:F1
|
Operation temperature |
-10 °C to +60 °C / +14 °F to +140 °F
|
Storage / Transport temperature |
-10 °C to +60 °C / +14 °F to +140 °F
|
Thermal load |
0.11 MJ/m
|
Flammability vertical single cable |
Pass
|
Flammability vertical single cable test method |
IEC 60332-1-2
|
Smoke density |
Pass
|
Smoke density test method |
IEC 61034-2
|
Halogen free, acid gases |
Pass
|
Halogen free, acid gases test method |
IEC 60754-2
|
2015 / 863 / EU - RoHS 3 |
conform
|