Stranded loose tube, gel-free cable, iRP-increased rodent protected, universal-u - eCatalog

eCatalog

Stranded loose tube, gel-free cable, iRP-increased rodent protected, universal-use, UV.FRLSZH sheath - yellow, B2ca, 4 x 12f = 48 fibers G657A1

Article no.: R873700
EAN / GTIN: 7611821013846
Delivery Unit: 1
Unit of Measure: Meter

Gel-free, improved rodent-protected, 6-way stranded loose tube cable, equippedwith 48 fibers. It is non-metallic but longitudinally watertight for installation in indoor or outdoor ducts (universal application). The cable construction is specifically designed to meet the CPR fire classification B2ca.

Technical Data
Cable family code UTd6x2,3GF FiRis 04.12
Cable type Stranded loose tube cable
Cable version Gel-free installation cable
Cable application universal use
CPR classification B2ca-s1a,d0,a1
DoP number D9093
Fiber type G.657.A1
Fiber count 48
Fiber color coding 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber count per tube 12
Loose tube count 4
Loose tube diameter 2,3 mm
FRP/coat. CSM nominal thickness [mm] 2.5
Armor Rodent protection
Outer sheath thickness 1,4 mm
Outer sheath material UV stable FRLSZH
Sheath marking Ink-Jet, black
Cable outer diameter 10,6 mm
Cable weight 120.0 kg/km / 80 lbs/1000ft
DIN / VDE 0888 code U-BQ(ZN)BH 4x2,3
Warranty R&Mfreenet
Expected lifetime min. 30 years
CPR test method EN 50575, EN 13501-6
Standard put-up length on drum 2’100 m ± 5%
CPR classification B2ca
Minimum bending radius no tension - 10 x cable diameter
Mechanical Data
In-service tensile strength 2200 N
In-service tensile strength acceptance criteria Δα ≤ 0,05 dB
In-service tensile strength test method IEC 60794-1-21:E1
Installation tensile strength 4000 N
Installation tensile strength acceptance criteria Δα ≤ 0,05 dB after test
Installation tensile strength test method IEC 60794-1-21:E1
Crush resistance long term 2000 N/100mm
Long-term crush resistance acceptance criteria Δα ≤ 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 4000 N/100mm
Short-term crush resistance acceptance criteria Δα ≤ 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 10 Nm, 3 impacts, d=20 mm, R=300 mm
Impact resistance acceptance criteria Δα ≤ 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E4
Torsion L = 1 m, rotation angle ±180°, 10 cycles
Torsion acceptance criteria no damage
Torsion test method IEC 60794-1-21:E7
Repeated bending R=20 x cable diameter, 25 cycles
Repeated bending acceptance criteria no damage
Repeated bending test method IEC 60794-1-21:E6
Cable bend d=20 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria Δα ≤ 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 160 mm
Minimum bend radius during installation 215 mm
Loose-tube colour coding 1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black)
Environmental Characteristics
Temperature cycling -40 °C +70 °C / -40 °F +158 °F
Temperature cycling acceptance criteria Δα ≤ 0,05 dB
Temperature cycling test method IEC 60794-1-22:F1
Operation temperature -40 °C to +70 °C / -40 °F to +158 °F
Storage / Transport temperature -40 °C to +70 °C / -40 °F to +158 °F
Water penetration L = 3 m, h = 1 m, 24 h
Water penetration acceptance criteria no water leakage
Water penetration test method IEC 60794-1-22:F5B
Thermal load 1.8 MJ/m
Flammability vertical single cable Pass
Flammability vertical single cable test method IEC 60332-1-2
Flammability vertical cable bundle Pass
Flammability vertical cable bundle test method IEC 60332-3-22
Smoke density Pass
Smoke density test method IEC 61034-2
Halogen free, acid gases Pass
Halogen free, acid gases test method IEC 60754-2
2015 / 863 / EU - RoHS 3 conform