Central loose tube, gel-free cable, RP-rodent protected, indoor-use, FRLSZH sheath - lime green, B2ca, 01 x 16 fibers OM5

Article no.: R857790
EAN / GTIN: 7611821017660
Delivery Unit: 1
Unit of Measure: Meter

Rodent protected, non-metallic and dry central loose tube cable for up to a maximum of 24 fibers for indoor duct installation.

Technical Data
Cable family code IFEF FiRis
Cable type Central loose tube cable
Cable version Gel-free installation cable
Cable application indoor use
CPR classification B2ca-s1a,d0,a1
DoP number D9082
Fiber type OM5
Fiber count 16
Fiber color coding 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink(ring-marked)
Fiber count per tube 24
Loose tube count 1
Loose tube diameter 2,4 mm
Armor Rodent protection
Outer sheath thickness 0,9 mm
Outer sheath material FRLSZH
Outer sheath color lime green
Cable outer diameter 5,4 mm
Cable weight 32.0 kg/km / 21 lbs/1000ft
DIN / VDE 0888 code J-B(ZN)H
CPR test method EN 50575, EN 13501-6
Standard put-up length on drum 2100 m ± 5%
CPR classification B2ca
Mechanical Data
Installation tensile strength 1000 N (5 min.)
Installation tensile strength acceptance criteria Δα ≤ 0,05 dB after test
Installation tensile strength test method IEC 60794-1-21:E1A
Crush resistance long term 500 N/100mm (15min)
Long-term crush resistance acceptance criteria Δα ≤ 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 1000 N/100mm
Short-term crush resistance acceptance criteria Δα ≤ 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 5 Nm, 3 impacts, d=20 mm, R=12,5 mm
Impact resistance acceptance criteria no fiber breakage
Impact resistance test method IEC 60794-1-21:E4
Torsion L = 1 m, rotation angle ±180°, 10 cycles, F= 20N
Torsion acceptance criteria no fiber breakage
Torsion test method IEC 60794-1-21:E7
Kink d=20 x cable diameter
Kink acceptance criteria no kink
Repeated bending R=10 x cable diameter, 25 cycles, m = 4Kg
Repeated bending acceptance criteria no damage
Repeated bending test method IEC 60794-1-21:E6
Cable bend R=20 x cable diameter, 6 turns, 10 cycles
Cable bend acceptance criteria no fiber breakage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 85 mm
Minimum bend radius during installation 110 mm
Environmental Characteristics
Temperature cycling -20 °C +60 °C / -4 °F +140 °F
Temperature cycling acceptance criteria Δα ≤ 0,05 dB
Temperature cycling test method IEC 60794-1-22:F1
Reversible temperature cycling -25 °C +60 °C / -13 °F +140 °F
Reversible temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible
Reversible temperature cycling test method IEC 60794-1-22:F1
Operation temperature -20 °C to +60 °C / -4 °F to +140 °F
Storage / Transport temperature -25 °C to +60 °C / -13 °F to +140 °F
Thermal load 0.48 MJ/m