Technical Data
Cable family code |
IFEF FiRis
|
Cable type |
Central loose tube cable
|
Cable version |
Gel-free installation cable
|
Cable application |
indoor use
|
CPR classification |
B2ca-s1a,d0,a1
|
DoP number |
D9082
|
Fiber type |
OM2
|
Fiber count |
16
|
Fiber color coding |
1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink(ring-marked)
|
Fiber count per tube |
24
|
Loose tube count |
1
|
Loose tube diameter |
2,4 mm
|
Armor |
Rodent protection
|
Outer sheath thickness |
0,9 mm
|
Outer sheath material |
FRLSZH
|
Outer sheath color |
orange
|
Cable outer diameter |
5,4 mm
|
Cable weight |
32.0 kg/km / 21 lbs/1000ft
|
DIN / VDE 0888 code |
J-B(ZN)H
|
CPR test method |
EN 50575, EN 13501-6
|
Standard put-up length on drum |
2100 m ± 5%
|
CPR classification |
B2ca
|
Mechanical Data
Installation tensile strength |
1000 N (5 min.)
|
Installation tensile strength acceptance criteria |
Δα ≤ 0,05 dB after test
|
Installation tensile strength test method |
IEC 60794-1-21:E1A
|
Crush resistance long term |
500 N/100mm (15min)
|
Long-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB prior release, no damage
|
Long-term crush resistance test method |
IEC 60794-1-21:E3A
|
Short-term crush resistance |
1000 N/100mm
|
Short-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB after release, no damage
|
Short-term crush resistance test method |
IEC 60794-1-21:E3A
|
Impact resistance |
5 Nm, 3 impacts, d=20 mm, R=12,5 mm
|
Impact resistance acceptance criteria |
no fiber breakage
|
Impact resistance test method |
IEC 60794-1-21:E4
|
Torsion |
L = 1 m, rotation angle ±180°, 10 cycles, F= 20N
|
Torsion acceptance criteria |
no fiber breakage
|
Torsion test method |
IEC 60794-1-21:E7
|
Kink |
d=20 x cable diameter
|
Kink acceptance criteria |
no kink
|
Repeated bending |
R=10 x cable diameter, 25 cycles, m = 4Kg
|
Repeated bending acceptance criteria |
no damage
|
Repeated bending test method |
IEC 60794-1-21:E6
|
Cable bend |
R=20 x cable diameter, 6 turns, 10 cycles
|
Cable bend acceptance criteria |
no fiber breakage
|
Cable bend test method |
IEC 60794-1-21:E11A
|
Minimum bend radius in service |
85 mm
|
Minimum bend radius during installation |
110 mm
|
Environmental Characteristics
Temperature cycling |
-20 °C +60 °C / -4 °F +140 °F
|
Temperature cycling acceptance criteria |
Δα ≤ 0,05 dB
|
Temperature cycling test method |
IEC 60794-1-22:F1
|
Reversible temperature cycling |
-25 °C +60 °C / -13 °F +140 °F
|
Reversible temperature cycling acceptance criteria |
Δα ≤ 0,15 dB, reversible
|
Reversible temperature cycling test method |
IEC 60794-1-22:F1
|
Operation temperature |
-20 °C to +60 °C / -4 °F to +140 °F
|
Storage / Transport temperature |
-25 °C to +60 °C / -13 °F to +140 °F
|
Thermal load |
0.48 MJ/m
|