Central loose tube, single sheathed cable, RP-rodent protected, outdoor- use, UV - eCatalog

eCatalog

Central loose tube, single sheathed cable, RP-rodent protected, outdoor- use, UV.LDPE sheath - black, Fca, 01 x 04 fibers OM3

Article no.: R855502
EAN / GTIN: 7611821025313
Delivery Unit: 2.100
Unit of Measure: Meter
Rodent protected, non-metallic central loose tube cable for up to a maximum of 12 fibers for outdoor duct installation.

Technical Data
Cable family code OT1EL
Cable type Central loose tube cable
Cable version n.a.
Cable application outdoor use
DoP number D9905
Fiber type OM3
Fiber count 4
Fiber color coding 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber count per tube 12
Loose tube count 1
Loose tube diameter 2,8 mm
Armor Rodent protection
Outer sheath thickness 1 mm
Outer sheath material UV stable LDPE
Outer sheath color black
Sheath marking Ink-Jet, white
Cable outer diameter 5,8 mm
Cable weight 29.0 kg/km / 19 lbs/1000ft
DIN / VDE 0888 code A-DQ(ZN)2Y
CPR test method EN 50575, EN 13501-6
Standard put-up length on drum 2100 m ± 5%
CPR classification Fca
Mechanical Data
In-service tensile strength 1000 N
In-service tensile strength acceptance criteria Δα ≤ 0,05 dB after test
In-service tensile strength test method IEC 60794-1-21:E1
Installation tensile strength 300 N
Installation tensile strength acceptance criteria Δα ≤ 0,05 dB
Installation tensile strength test method IEC 60794-1-21:E1
Crush resistance long term 1000 N/100mm
Long-term crush resistance acceptance criteria Δα ≤ 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 2000 N/100mm
Short-term crush resistance acceptance criteria Δα ≤ 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 10 Nm, 3 impacts, d=20 mm, R=300 mm
Impact resistance acceptance criteria Δα ≤ 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E6
Torsion L = 1 m, rotation angle ±180°, 10 cycles
Torsion acceptance criteria no damage
Torsion test method IEC 60794-1-21:E7
Repeated bending R=20 x cable diameter, 25 cycles
Repeated bending acceptance criteria no damage
Repeated bending test method EN 60794-1-21:E6
Cable bend d=20 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria Δα ≤ 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 90 mm
Minimum bend radius during installation 130 mm
Environmental Characteristics
Temperature cycling -20 °C +70 °C / -4 °F +158 °F
Temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible
Temperature cycling test method IEC 60794-1-22:F1
Reversible temperature cycling -25 °C +70 °C / -13 °F +158 °F
Reversible temperature cycling test method IEC 60794-1-22:F1
Operation temperature -20 °C to +70 °C / -4 °F to +158 °F
Storage / Transport temperature -25 °C to +70 °C / -13 °F to +158 °F
Thermal load 0.86 MJ/m
2015 / 863 / EU - RoHS 3 Pass