Rodent protected, non-metallic central loose tube cable for up to a maximum of 12 fibers for outdoor duct installation.
Technical Data
Cable family code |
OT1EL
|
Cable type |
Central loose tube cable
|
Cable version |
n.a.
|
Cable application |
outdoor use
|
DoP number |
D9905
|
Fiber type |
OM3
|
Fiber count |
4
|
Fiber color coding |
1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
|
Fiber count per tube |
12
|
Loose tube count |
1
|
Loose tube diameter |
2,8 mm
|
Armor |
Rodent protection
|
Outer sheath thickness |
1 mm
|
Outer sheath material |
UV stable LDPE
|
Outer sheath color |
black
|
Sheath marking |
Ink-Jet, white
|
Cable outer diameter |
5,8 mm
|
Cable weight |
29.0 kg/km / 19 lbs/1000ft
|
DIN / VDE 0888 code |
A-DQ(ZN)2Y
|
CPR test method |
EN 50575, EN 13501-6
|
Standard put-up length on drum |
2100 m ± 5%
|
CPR classification |
Fca
|
Mechanical Data
In-service tensile strength |
1000 N
|
In-service tensile strength acceptance criteria |
Δα ≤ 0,05 dB after test
|
In-service tensile strength test method |
IEC 60794-1-21:E1
|
Installation tensile strength |
300 N
|
Installation tensile strength acceptance criteria |
Δα ≤ 0,05 dB
|
Installation tensile strength test method |
IEC 60794-1-21:E1
|
Crush resistance long term |
1000 N/100mm
|
Long-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB prior release, no damage
|
Long-term crush resistance test method |
IEC 60794-1-21:E3A
|
Short-term crush resistance |
2000 N/100mm
|
Short-term crush resistance acceptance criteria |
Δα ≤ 0,05 dB after release, no damage
|
Short-term crush resistance test method |
IEC 60794-1-21:E3A
|
Impact resistance |
10 Nm, 3 impacts, d=20 mm, R=300 mm
|
Impact resistance acceptance criteria |
Δα ≤ 0,05 dB after test, no damage
|
Impact resistance test method |
IEC 60794-1-21:E6
|
Torsion |
L = 1 m, rotation angle ±180°, 10 cycles
|
Torsion acceptance criteria |
no damage
|
Torsion test method |
IEC 60794-1-21:E7
|
Repeated bending |
R=20 x cable diameter, 25 cycles
|
Repeated bending acceptance criteria |
no damage
|
Repeated bending test method |
EN 60794-1-21:E6
|
Cable bend |
d=20 x cable diameter, 4 turns, 3 cycles
|
Cable bend acceptance criteria |
Δα ≤ 0,05 dB after test, no damage
|
Cable bend test method |
IEC 60794-1-21:E11A
|
Minimum bend radius in service |
90 mm
|
Minimum bend radius during installation |
130 mm
|
Environmental Characteristics
Temperature cycling |
-20 °C +70 °C / -4 °F +158 °F
|
Temperature cycling acceptance criteria |
Δα ≤ 0,15 dB, reversible
|
Temperature cycling test method |
IEC 60794-1-22:F1
|
Reversible temperature cycling |
-25 °C +70 °C / -13 °F +158 °F
|
Reversible temperature cycling test method |
IEC 60794-1-22:F1
|
Operation temperature |
-20 °C to +70 °C / -4 °F to +158 °F
|
Storage / Transport temperature |
-25 °C to +70 °C / -13 °F to +158 °F
|
Thermal load |
0.86 MJ/m
|
2015 / 863 / EU - RoHS 3 |
Pass
|