Technical Data
Wire type |
Wire or stranded wire
|
Conductor Construction |
AWG 22 - 26
|
Wire diameter |
Wire: 0.4 - 0.61mmStranded wire: 0.12mm2 - 0.32mm2
|
Approved wire diameter with insulation |
1,6 mm
|
Number of wires |
8
|
Cable overall diameter |
5.0 - 8.5mm
|
Shield jacket material |
Brass (CuZn) hot-dip galvanized, 3µm
|
Protection class IP |
IP 67 (correlates to NEMA 6P)
|
Pollution Degree |
2 according to IEC 61010-1
|
Dust Protection |
Yes
|
Wiring diagram |
T568A and T568B
|
Colour Coding |
Yes, optional
|
Contact material |
Bronze (CuSn6)
|
Contact Surface |
>1.2µm gold over 1.2µm nickel
|
Re-termination |
≥4 according IEC 60352-4Re-terminations may be performed with wire of either larger or equal size than originally terminated.
|
UL Classification |
UL94-V0
|
Approved wire diameter with insulation |
1.6 mm / 0.063 in
|
Mechanical Data
Dimensions |
77.0 mm x 22.8 mm x 38.4 mm / 3.031 in x 0.898 in x 1.512 in (W x H x D)
|
Design |
straight
|
Color |
Plug: tranparentHousing: traffic gray (RAL 7042)
|
Connection Type |
IDC according IEC 60352-4*, tin-plated, approx. 5µm*Re-terminations may be performed with wire of either larger or equal size than originally terminated.
|
Mating Cycles |
> 750
|
Material |
Polycarbonate (plug) polyamide (housing)
|
Environmental Characteristics
Operation temperature |
-20 °C to +70 °C / -4 °F to +158 °F
|
Electrical Data
Nominal Current |
1.55A @20°C
|
Input-Output Resistance |
< 100 mΩ
|
Insulation Resistance |
> 1GΩ (100V)
|
Contact Resistance |
Wire - IDC < 1mΩStranded wire - IDC < 5mΩSignal contact - screen < 20mΩ
|
Dielectric Strength |
Contact - contact >1000VDCShield - contact >1500VDC, 1min.
|
Standard |
ISO/IEC 11801
IEC 60603-7-41/51
EN 50173
ANSI/TIA-568-C.2
PoE (IEEE 802.3af), PoEP (IEEE 802.3at), 4PpoE (IEEE 802.3bt)
IEC 60512-00-001/002
|